Profile Log out

Supermicro disable ipmi failover

Supermicro disable ipmi failover. Follow the section Setting advanced configuration options using the vSphere Client for ESX/ESXi 3. 0 Password Hash Disclosure – that is CVE-2013-4786, our document showed it is fixed in X9 firmware 3. Select “Controller Properties”. Feb 9, 2022 · BMC IP address appears in the bottom right during POST. How to reconfigure IPMI using ipmitool? This article provides the steps to change the IPMI network settings on Nutanix nodes using the command-line tool ipmitool. Supermicro BMC solution can configure BIOS secure features, Secure Boot, and Secure Drive Erase via Redfish's secure interface. 4. May 7, 2015 · IPMI plugin for unRAID 6. chrisolson09 said: In my research it says that when you run IPMI over a LAN port that it has to be the LAN1 port, the problem comes in for me though is that this board does not have the LAN1/2 ports based on the schematicit only has the 3/4 LAN ports and I'm wondering if this is the reason why it's not working. 1+. – That is CVE-2013-4782, CVE-2013-4783, CVE-2013-4784, CVE-2014-2955. While the IPMI standard protocol defines UDP port 623 for RMCP communications, there are additional remote services that BMCs provide to efficiently provision and debug servers. Doing some research, I found this Mar 15, 2012 · Make sure it is what you expect it to be. 其命令列工具提供了標準 IPMI 指令與 Supermicro 專屬的 OEM 指令用於作 BMC/FRU 配置。. 38cm) Processor. exe req -out node1ipmi. Release Notes. 3. Make the IPMI VLAN a native VLAN on the switchport, and disable VLAN tagging for IPMI on your Supermicro. IPMI version 2. x also enabled redfish support and credential verification via secure LDAP. Use it for basic IPMI configuration and BMC status reading and monitoring. Supermicroは、定期的なファームウェア Or you can use IPMICFG by doing the following: Run ipmicfg as administrator, to check the current lan mode: ipmicfg -raw 0x30 0x70 0x0c 00 it will return value: 00 = dedicated, 01 = share, 02 = failover to change lan mode: ipmicfg -raw 0x30 0x70 0x0c 01 0# (in place of the # you can use 0 = dedicated, 1 = share, 2 = failover) You may also use the shared IPMI/1G port in place of the dedicated port, as long as the BMC is configured to use it, but it is less reliable than the dedicated port. 具备基板控制器 (BMC Supermicro | Server Storage, Innovation, Cloud and AI We would like to show you a description here but the site won’t allow us. The management interface prompts for login credentials. Dec 30, 2020 · It’s important to know this! Supermicro has a default password of ADMIN. If its untagged on the switch you won't need to specify the vlan id in your ipmi config. We now feed OpenSSL the configuration and private key files and instruct it to output a new CSR. SMCIPMITool Key Features: Remote IPMI Management. This command can be used to enable or disable non-IPMI services such as ssh, http, https, and vnc. If no IP address shows up then of course you won't be getting into the IPMI. Initially, we log into the panel and click the Maintenance tab. The Supermicro X13/H13/X12/H12 platform's BMC (Baseboard Management Controller) is built on the ASPEED AST 2600. Log in to the management interface. There's an argument tag set in the jnlp file that's left blank. If your default username and password is something like “admin / admin”, “root / password”, “root / calvin” for Dell EMC, “ADMIN / ADMIN” for Supermicro, or similar, it is exceedingly easy for a malicious user to try default logins. F. I mistakenly updated the firmware first through IPMI, then tried to update bios. Was this FAQ helpful? In general, you will need NIC with NCSI interface and SI cable to connect the NIC to the NCSI header on the motherboard to BMC. Dec 16, 2023 · Select the controller affected by the issue. It's always a good idea to upgrade IPMI firmware, for security reasons, add functionalities as IPKVM/Html5; as long as I know, you can downgrade it to an earlier version in the same "major" revision, meaning if your firmware version is 3. 19 and above. To update the BIOS from the management panel. mynet, and try to start up the java KVM then the jnlp file created by IPMI doesn't get the server IP address properly populated. 38cm x 24. Thank you for the info! I will have to fire up IPMI, as I haven't played with it (recent servers are Dell). IPMI connection could go through LAN 1 when dedicated port connection gets lost in failover mode. 1c). In order to disable the IPMI, please login the IPMI site and select Configuration -> LAN Select -> Enable -> Dedicated LAN (only) then click SET to save it. For X12DDW, you will need AIOM NIC IPMICFG 是一款用來配置 IPMI 裝置的本機端 (In-band/Local) 工具。. Our IPMI firmware only supports TLS 1. T. 0 Management. 0-U6. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) V. Share the IPMI VLAN with something else that the ESXi host is using, such as management, if you’re using a switch that can only provide For question 3, the answers are in both manuals. You can use IPMICFG utility to disable the sensor. but i unplugged the IPMI cable, it is not failover to LAN1 on X9SCM-F, while LAN1 is also used by esxi. S. ASUS WS C621E SAGE ASMB9 IKVM Login. com (Technical Support) Web Site: www. #7. #2. C:\OpenSSL\bin>openssl. To recover from this, you need to reset it to factory defaults locally. Remote NM (Node Manager) 2. If i changed the "Lan Interface" from default "Failover" to "Share" or "Dedicate" the IPMI Webinterface is unreachable. authorized representative) assume the entire cost BMC/IPMI Virtual Media is a feature of the Virtual Console that enables users to attach a CD/DVD image to the server as a virtual CD/DVD drive. Identified by researchers in the lab, the vulnerabilities have When IPMI Lan Selection set in "Failover" mode then which AIOM-LAN is activated for IPMI failover? Answer The LAN port of JAIOM1, which is on the left hand side of the MB, is activated for this Failover IPMI LAN Selection. Command confirmed to work on Supermicro X8DTG. Extract the archive and copy the contents of the 'DOS' folder on to your bootable DOS USB. You can do this by connecting to IPMI using a web browser. Sep 3, 2013 · Reply Reply Privately. Dec 22, 2016 · Contacting Supermicro Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. Rev. For information on Backpanel USB and Front Panel USB ports, refer to page 2-21. supermicro. By default it is set to Failover, meaning if it does not detect connection on Dedicated, it will look for connection on Shared and IPMI will run on that port. miguellee said: The IPMI if function ok on the dedicated lan port. Java web start IKVM failure: If I access IPMI through a DNS name, for example: ipmi. IPMI KVM (X9DRD-if motherboard, SuperMicro server) WORKED WITH. CPU. To set up the NTP: 1. After that, you can un-plug the network cable at Dedicate LAN Port. For X12DPU, the NICs on the Ultra raiser are on-board NICs. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) IPMI 2. g. Enter your email address below if you'd like a technical support staff to reply: FAQ Stats. cfg. You will also find links to other resources and guides on IPMI configuration and troubleshooting. Show entries. 設定 IPMI IP 位址 Jul 24, 2020 · In the IPMI web interface, you can disable the in-band interface to preclude any possibility of interference with the main LAN interface. Go to Configuration > Network, and scroll down to the drop-down list for LAN Interface, or Default Interfaces. In IPMI Web UI, select "Date & Time" from the Configuration menu. It will only work on the port closest to the IPMI dedicated port. 1 Features If you put Rule 1 as 0. Watchdog is enabled in BIOS settings. The Standard Speed profile is temperature controlled, with a base fan speed at 50% PWM duty cycle. The Aug 21, 2019 · I bought a Supermicro X10SLM-F off ebay and it had a very old firmware and bios. This includes a KVM Console function. 1. Example of CLI : Ipmitool –H 172. Chrome works 100% fine. See the Notes section of this article for more information on failover, shared or dedicated configurations. 0 with virtual media over LAN and KVM-over-LAN support; ASPEED AST2400 with 10/100/1000M bps MAC; Network Controllers: Intel® Ethernet Controller I210-ATIntel® Ethernet Controller I217LMSupports 10Base-T, 100BASE-TX, and 1000BASE-T, RJ45 outputRealtek RTL8211E PHY (dedicated IPMI) Graphics: Aspeed AST2400 BMC Aug 11, 2016 · Problem is, my previous experience with X11SCA-F indicates it's not possible to have IPMI IKVM + active external display at the same time. Sensor reading color will be green if between non critical, yellow for critical and red for non recoverable. The link I posted tells you how to unlock the remote BIOS Update License. Set NTP Server to the name of the NTP server. Supermicro X10SL7-F. If you're not seeing the IPMI, that may be bad. Use safari or internet explorer. 1 build, running since 9. IPMICFG 是一款用来配置 IPMI 装置的本机端 (In-band/Local) 工具。. 0. IPMICFG. During the bootup process, my screen tells me the IP address and you need to ensure you are using that one. Event Log can clear all or individual events. csr -key node1ipmi. com (General Information) support@supermicro. The only thing actually using Java is the KVM client, which is downloaded as a JNLP file anyway. For the Supermicro Server Manager question, it requires IPMI IP and activated SPT-OOB-LIC on each IPMI for the SSM to detect the system. It is designed for easy to use and no pre-installation required. Aug 21, 2019 · I bought a Supermicro X10SLM-F off ebay and it had a very old firmware and bios. To do this, re-boot the server and press Del (for Supermicro motherboards) during the Power-On Self-Test (POST). Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro. Wait for IPMI to go out. IPMI has a failover option - it'll switch IPMI interface to one of the standard ethernet ports, and often in my experience fail to establish any connection if there's anything else using that port. This is the result of my experiment of X11SCA-F + viewsonic monitor 2407h which has both hdmi and vga output, the cpu is i5-8400t. Workaround #1: If you edit the downloaded jnlp file and add For IPMI v2. Some of these services include VNC for debugging an OS, access to http/https ports for locally configuring BMC settings and reading server health, and Here’s the link for the IPMI manual explaining setup and features. Changing NIC failover mode. 6" x 9. Nov 16, 2009 · If you have physical access to the server, follow these simple steps to reset the ADMIN password on your IPMI: Create a bootable DOS USB stick using Rufus. 2” >> then push Apply and OK button >> to fix this issue on IE 10. Sensors can be viewed in basic or advanced mode. . Mar 25, 2018. As a result, IT administrators can take advantage of these two security features while provisioning or maintaining a system. May 31, 2015 · 5. Show : 13. RE: How to disable IPMI. The popups are caused by Supermicro being dumb. Jun 17, 2006 · The failover option makes the nic act like a three port switch with IPMI, normal i210 nic and the connection to the rest of your network. I believe the alarm is occurring because of the chassis intrusion detection since I have the chassis open currently. These addressed issues for Java and moved many iKVM's over to HTML5. V. This OEM command will enable or disable all non-IPMI services on the BMC. Sep 14, 2015 · Tag the IPMI VLAN on your switchport and input the VLAN ID into the Supermicro network settings page. To disable/silence alarm from MegaRAID Storage Management: Select the controller affected by the Supermicro | Server Storage, Innovation, Cloud and AI To be able to change network settings of IPMI, this parameter should be set to disable to the time of change. IPMICFG 产品特点:. key -new -config node1ipmi. This plugin is for viewing the local or remote sensors and event logs of a motherboard with ipmi. 1, Supermicro X10SL7-F with G3258 CPU, 16 GB ECC RAM, 8x 4TB WD Red in RAIDZ2 (encrypted) in Fractal-Design Node 804 case. or super micro computer inc. Make sure you've got your network plugged into the IPMI port. com. Model. Disable DHCP. by super micro computer inc. You need a router to access it from another Lan. 10 not 2. xx. exe –fd. 30 you can downgrade it to 3. Linux Virtual Machine + Firefox inside MacBook at home connected by wifi to a ROUTER WITH STATIC IP. 0 or greater. But apparently Mouse + keyboard input works during blackscreen. exe -dhcp off. Jan 26, 2016 · Jan 26, 2016. Nutanix Support & Insights Loading Sep 7, 2017 · SMCIPMITool is an out-of-band Supermicro utility that allows a user to interface with SuperBlade systems and IPMI devices via CLI (Command Line Interface). 此命令列介面工具可在 UEFI、DOS、Windows 与 Linux 操作系统上执行,毋需安装。. Up to 6 cores, 12 threads. Oct 27, 2015 · LAN Interface: This feature allows the user to select the port to be used for IPMI out-of-band communication. 32GB 2x Crucial ECC DDR3 1600 CT2KIT102472BD160B. Windows 7 + IE7 + Java7 at home connected by LAN in a ROUTER WITH STATIC IP. Alternatively, you can press the DEL key during POST to enter the BIOS and then navigate to IPMI > BMC Network Configuration. #3. Answer: In basic terms, "dedicate" mode is using the dedicated IPMI port connection. IPMI plays very little part in the boot process under normal circumstances. I've actually had to do the following to get IPMI working: Configure IPMI to use either dedicated IPMI or sideband IPMI. Enter Comments Aug 6, 2021 · Aug 6, 2021. 0” and check “use TLS 1. Description. Was this FAQ helpful? YES NO. This is an expected behavior as the BIOS code can’t auto bypass BMC step by detecting jumper status. You don't mention if you are using the dedicated IPMI port or using the IPMI port in shared mode on the primary interface. Macbook + Chrome + Java7 at home connected by wifi to a ROUTER WITH STATIC IP. FAQ ID. Log into the IPMI web interface by entering the IP address into the URL of a web browser on a client system. X10SLM+/X10SLL+ Motherboard Series User's Manual Connecting Cables This section provides brief descriptions and pin-out definitions for onboard headers and connectors. 11 –U ADMIN –P ADMIN raw 0x30 0x70 0x0C 1 0 // for ATEN LAN mode get: Input : NetFn 0x30 Cmd 0x70 Param1 0x0c Param2 0 [read] Output: Completion Code 0x00 Data [dedicated/onBoard/failover] LAN mode set: Input : NetFn 0x30 Cmd 0x70 Param1 4. The fix is to change the setting from "Failover" to "Dedicated". Mar 25, 2018 · 15. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) Jan 10, 2017 · 1. 6" (24. SFT-OOB-LIC. Xeon E-3 1240V3. 3 (2015) Supermicro 721TQ-350B NAS case (replaced Norco ITX-S4 2021) Currently the port on the L2 switch is empty for VLAN1 and Untagged for VLAN10. 0 is not supported. May 29, 2018. A. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) N. TrueNAS 13. However a simple explanation is that our boards has two ports for IPMI. You need an unlock code from Supermicro to update the BIOS through IPMI. 3. Messages. should the software and/or materials prove defective, you (and not super micro computer inc. If you go into the IPMI web interface you can change the failover mode. "Share" is using LAN1 as primary IPMI connection. Please email to support@supermicro. 6x8TB Shucked WD Easystore RAIDZ2. BIOS Configuration. 8th/9th Generation Intel® Core™ i3/Pentium®/Celeron® Processor, Intel® Xeon® E-2100 Processor, Intel® Xeon® E-2200 Processor. exe –conf tdownload <file>. IPMI does not work on LAN2. For step 6 look for VMkernel. I would like to know if I can somehow tell the BMC to not sound an audible alarm when the chassis cover is off because I frequently need to have it off. #1. IE 10 by default still uses TLS 1. In this case watchdog works as expected -- system was stable for 25 minutes with bmc-watchdog running and rebooted after watchdog program termination. The default setting is Failover, which will allow IPMI to be connected from either the shared LAN port (LAN1/0) or the dedicated IPMI LAN port. Here you can change the default administrative user name and Yes. Use the following guideline when connecting the IPMI port on G4 and later platforms: if you use the shared IPMI port, make sure that the connected switch can auto-negotiate to 100 BIOS & BMC & Bundled & Microcode Package Download. Let the capacitors bleed. 10,080. The next step is to submit the CSR to your certificate authority (CA) – of course the instructions here The BIOS and the IPMI are totally separate, except that the IPMI can write to the BIOS in order to update it. Motherboard Type: BIOS for older products. AST2600’s design is specifically based on Dual-core ARM Cortex A7 and various hardware interfaces including as Root of Trust (RoT), MCTP over PCIe, and dual JTAG master, supporting modern remote manageability on Supermicro platforms. (This is the tricky part) Unplug power from the machine. ipmitool lan set 1 ipsrc dhcp. Reset to the factory default. For security purposes, TLS 1. Be sure to use the correct cable for each header or connector. May 15, 2016 · Until today I tought it would be safe to simply unplug the IPMI cable. ipmitool lan set 1 access off. この CLI ベースのユーティリティは、UEFI、DOS、Windows、Linux の OS 上で実行する Oct 19, 2018 · The basic BMC and IPMI default logins are well-known. # ipmiutil smcoem lanport failover Connecting to the IPMI interface. Note: Your comments/feedback should be limited to this FAQ only. As soon as you setup your IPMI on a Supermicro system, remember to change the default password right away. or a super micro computer inc. 6. To configure the network settings for the IPMI module in the BIOS, you must first start the server and enter the BIOS. 168. IPMICFG は、IPMI デバイスを構成するためのインバンドユーティリティで、標準の IPMI と Supermicro® 独自の BMC/FRU 向け OEM コマンドを提供するコマンドラインツールです。. Enter Comments Below: Note: Your comments/feedback should be limited to this FAQ only. May 29, 2018 · May 2, 2015. If there is nothing plugged into the IPMI they just 'share' the normal LAN port to expose IPMI to the network. Boot. For IPMI initialization, no matter you shift the JPB1 jumper to enable or disable BMC, BIOS still do IPMI initialization and the time required to boot is almost the same. On Supermicro servers, IPMI can be configured either by using an open-source utility called IPMItool or by using BIOS through a VGA console or by using IPMICFG (Supermicro proprietary tool). Download the latest IPMICFG utility released by Supermicro. To adjust your fan speed profile, you can use either Supermicro's IPMICFG, or set it from the IPMI web interface. Helpdesk@bytesizedalex. All three NIC´s (Dedicated IPMI, NIC 0 and 1) are connected to the network, but the Webinterface is unreachable. BU Server: TrueNAS-13. Dec 3, 2019 · Update Supermicro BIOS using IPMI. IPMI service is affected by an authentication bypass. authorized representative shall create a warranty or in any way increase the scope of this warranty. San Jose, CA 95131 U. IPMICFG-Windows. impiEnabled and set value 0 or unchecked. Jan 18, 2017 · emailAddress = IT. x in KB1038578 to disable. It is a command line tool providing IPMI commands and Supermicro proprietary OEM commands. x, and 5. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) 9. Select “Disable”, “Enable”, or “Silence” from the drop-down menu and click “Submit”. The default setting is Fail Over, which chooses to use either the dedicated IPMI port or the first set-bmc-services-status enable|disable. Reset IPMI unit to default factory setting to reverse the above process. Thus the BIOS can be updated from IPMI only if the license key is available. 50. Secure boot is part of the UEFI firmware standard (since 2. Go to Configuration -> Network and then change Lan Interface: to "Dedicated". Download ZIP 1. ipmicfg -sdr to find chassis intrusion sensor number. Note. 0-U5. ipmitool lan set 1 access on. You will typically be given three to five fan speed modes to choose from. May 5, 2017 · If you want to setup IPMI to work over the non-dedicated LAN port, leave it in Failover and assign a static IP. IPMI is required (since it monitors the sensor), and SSM aggregates all the IPMI’s in your datacenter and provides Note: Your comments/feedback should be limited to this FAQ only. Reboot IPMI unit to make setting effective. 0/0 and Block, then you put your IP as Rule 2 and Allow. Precedence is given to the Dedicated LAN port over the shared LAN port. com for more information. Mar 20, 2017 · I thought I was being prudent leaving IPMI disconnected but instead I was inadvertently exposing my whole network to a massive security hole. Supermicro 16GB SATA DOM. You can disable it in the BIOS. Jan 26, 2016 · Don't use chrome it has Java disabled partially. Click “Next” until locating the “Alarm Control” entry. It will prompt for a license key to activate components from the IPMI interface. jgreco said: The system will boot if it is set up to, and if it can. admin. 此命令列介面工具可在 UEFI、DOS、Windows 與 Linux 作業系統上執行,毋需安裝。. here. For technical support, please send an email to support@supermicro. P. Set "UTC Timezone" to the current offset (GMT-07:00 for PDT). Single Socket Socket H4 (LGA-1151) supported, CPU TDP supports Up to 95W TDP. In the System BIOS the "ipmi network link status" is "no connect" and the "ipmi lan selection" shows "share lan". Service ports. It is Dedicated and Shared (on LAN1). Jun 5, 2018 · Main System: TrueNAS-13. The Supermicro BMC sometimes tries to autodetect the IPMI port, and sometimes makes the wrong decision. You may set it to dedicated if you want IPMI connection stays at dedicated port. Supermicro IPMICFG User’s Guide 1. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) X. C. "Failover" allows for both dynamic and manual switch from dedicated port connection to LAN 1 when dedicated IPMI connection fails. Share. Eventually, I found a little bit strange solution: just leave watchdog jumper (JWD1) open (with neither NMI nor hard-reset selected). Subsequently, after completion of the POST, the main screen of the BIOS will be displayed. Hopefully this helps get your server set to the properties and security for your specifications. Tip: If you’re using an older Supermicro motherboard such as the X8, it’s auto detection can cause issues where IPMI stops responding. Check "Automatically synchronize Date & Time with NTP Server". These vulnerabilities include plaintext authentication, weak encryption, and authentication bypass within the Virtual Media capabilities. Title: Microsoft Word - Disable BMC Virtual Media Author: IgorD Created Date: 9/4/2019 11:26:45 AM In an effort to expand IPMI capabilities, many companies and organizations have built more extensive management control into IPMI using OEM extensions. Then we click on BIOS Upload from the Aug 16, 2015 · Set IP. The Java issue is largely taken care of now with any IPMI firmware 2. 1, Supermicro X10SRH-cF with E5 1650-v4 CPU, 96 GB ECC RAM, 8x 4TB WD Red in RAIDZ2 + 8x 4TB WD Red in RAIDZ2 as local backup pool in Norco RPC-4224 chassis. IPMICFG Overview IPMICFG is a utility for IPMI devices configuration. The failover works like this: if there is a link up on dedicated port, the system at start will used that. Enter your email address below if you'd like technical support staff to reply: Please type the Captcha (no space) 6. The IPMI/BMC audible alarm is sounding sporadically on the motherboard. Unplug it if you have no intention to use! On most Supermicro motherboards that won't help. exe -m 192. Two kinds of user modes are provided when you start the SMCIMPITool: Command Line Mode and Shell Mode. The problem is that once the bios got to 100% it was stuck there. 1. IPMICFG 產品特點:. IPMI Securityは進化した トピックであり、Supermicroは、自社製品のセキュリティーの向上やタイム リーなファイームウェア提供を行うため、積極的かつ継続的にITセキュリティー コミュニティーや顧客と取組んできました。. 980 Rock Ave. http ://<<ip address>) to use the SuperMicro IPMI web UI. 2. ledude1. However, it will silently fallback to LAN1 if there's no cable plugged into the IPMI connector! The quick reference guide that came with the board lists jumper JPB1, which "enables or disables BMC" (IPMI). ipmicfg -sdr del sensor_number to disable the alert. I've set a static IP. Refer to your IPMI device documentation to learn the default administrator account credentials. Mar 21, 2024 · Access the IPMI interface using a web browser and the IP address specified in Network > IPMI. 其命令行工具提供了标准 IPMI 指令与 Supermicro 专属的 OEM 指令用于作BMC/FRU 配置。. 2. Solution: switch the machine off, including PSU. Since most of the Supermicro motherboards that support IPMI have on-board NICs, so the 1st NIC becomes the IPMI failover. 9. Jan 1, 2011 · Here's what you need to do: take the LAN cable connected to the IPMI port. Changing fan speeds for X9/X10 series boards. Mar 8, 2018 · Mar 8, 2018. com Europe Address: Super Micro Computer B. Core. Please go to IE >> Internet Option >> Advanced >> uncheck “Use TLS 1. Here is how to do that correctly: syscfg /lfo disable. From the FAQ you yourself posted: Or if you have the OOB remote Bios update license, shut down the system and update the Bios using the IPMI remote interface. I rebooted and am caught in an infinite reboot loop, it never makes it to even the BIOS options, nor letting me boot from USB. 1 Recommend. Now, you can connect a browser to the IP (e. 31. Download IPMI Config to a text file. Here you can see the IP address as well as configure the settings such as a static IP address and gateway. This will block all access to the IPMI, since Rule 1 takes precedence over Rule 2 and will block all IP, even though you have Rule 2 set to allow your IP. pk bt oq qf tk ak pj cw ny rs