Predator 3500 overload. The featured design follows the latest trends and is ideal for easy and recreational use. I just posted an intro in the newbie page but need help with my new-to-me 2019 Forest River Wildwood Heritage Glen 272RL. Author Profile. E. If you are using a Predator 3500 Generator then you should read Troubleshooting of the Predator 3500 Generator to learn about basic problems. OVErLOaD OuTpuT pa raLLEL OuTS T a C 120VET DC 12V ESC THrO TTLE ru arT LOW OiL rLOaD OuTpuT raLLEL OuTLE TS SE C S DC 12V ESC THrO TTLE NEVER use inside a home or garage, EVEN IF doors and windows are open. A simple 1200 watt heater will cause the overload light to come on and the voltage rapidly drop. May 7, 2024 · Overload protection; This Predator 3500 watt super quiet inverter generator unit comes with an accessories kit. 8 x 17. Make sure to gap it to . That is a positive characteristic that will help you avoid trouble in crowded campsites. The Predator 3500. There are a few things to keep in mind when purchasing a Predator 3500 generator. Download Predator 57509 PDF manual. Finally, try to start the generator again. Recycle used oil. I built a custo May 17, 2024 · The Predator 3500 has a fuel tank capacity of 2. Over time, the reset button wears off, requiring replacement. 100% Satisfaction Guaranteed. If you continue to see tripping, contact a professional. No Hassle Return Policy. Once the device is back on, you reconnect your appliances one at a time while observing for signs of an overload. It will start momentarily and flash overload then quit. Sep 30, 2023 · The Predator 3500 comes with a 90-day warranty. Me, I like big and my wife likes her hair dryer and coffee maker, so I went 3500. Next, the choke lever may be positioned wrong. Amazon product. The 1/4 inch thick venturi installs in the predator 3500 easily using the ingenious capped bolt extensions to reconnect the air cleaner and venturi to the carburetor. 4 gallons. We own the above generator. It has a 120V output and a running power of 3,000W and a peak power of 3,500W. This fuel capacity can provide up to 8 hours of continuous power at 50% load. 0 gallons. First, disconnect the main source of power. 75 x 17. I have a 3500 predator Invertor super quiet generator from Harbor freight and a hardwired surge guard (model#35530) from camping world. It doesn't sound like the engine speeds up when this load (the 1200 watt heater) is plugged in. The predator 3500 is an ideal inverter generator for your RV, camping Bought Predator 4550 a week ago on a whim cause of the member discount. Then, check the spark plug and clean or replace it if necessary. In comparison, the Predator 3500 is more portable and, as a result, it’s better for tailgating and RVs. It will turn off automatically when there is an overload. A couple of sleeves need to be pushed out of the air cleaner bolt holes first. Subscribe. Coming in at just shy of 100 lbs while empty the Predator 3500 is hefty but still portable; measuring at 22. OFF run arT OiL OVErLOaD uT araL OuTLTS T aC 120V ET DC 12V ESCTTLE Only use OUTSIDE and far away from windows, doors, and vents. 8 x W17. The low-oil module could be defective. Symptoms of Generator Overload. 3500 Maximum Starting Watts Receptacles 2 x NEMA #5-20 (3-prong, 120 VAC) 1 x NEMA #L5-30 (3-prong, 120 VAC) 1 x 12 VDC Two Pin Outlet Displacement 212 cc Compression Ratio 8. 2 hours, while at a full load, the runtime will be significantly reduced to 8. However, you do get double handles for both machines. The AC was the only thing on, batteries were fully charged, and the gen started and ran fine for about 10 minutes, but then Aug 26, 2021 · You will have to pull the plugs, clean them, re-gap them and then test the spark. It puts out just 57 dB of noise at a 25% power load. To restart the generator, press and hold the reset button for one second (most manufacturers). If the Predator predator 3500 overload problems. Disconnect this wire from the module and tuck it aside. The first step is resetting your inverter generator by turning it off, unplugging all the things, resetting any GFCI outlets/breakers, and figuring out whether you were actually overloading the machine. Place an oil drain pan under the Generator and center under the Drain Plug opening. The emissions control system for this Engine is warranted for standards set by the U. It works with a 212cc air-cooled OHV engine; Long run time of 11 hours at 25% capacity; Digital LCD screen shows you oil, overload, and output PREDATOR 7600/9500 Watt Closed Frame Inverter Generator Item# 57080 Legacy UPC: 792363570800 | UPC: 792363570800 Part# Description Diagram Ref# Price 601049 STARTER MOTOR 84A Call for Pricing 601053 WHEEL KIT 12-14, 16 Call for Pricing 603124 COMBINATION SWITCH WITH KNOB NONE Call for Pricing 603478 FUEL TANK CAP NONE Call for Pricing Simply reset the generator. Disconnect sensor Predator 3500 Super Quiet Inverter Generator, Red. Nothing is plugged into it. You could probably run a 10,000 BTU air conditioner on the hottest day of the year, all day long, without refilling the gas tank. The manufacturer supplies you with a funnel, a tool kit, an RV adapter, and charging cables for your battery. Does this sound like an engine speed regulator problem? Apr 13, 2020 · 2. Generac iQ3500 also comes with a handle for easier portability. In regard to the Champion 100263 3400-Watt, there is a convenient ignition switch to help you monitor the unit easier. See full list on campertroop. Yes, this is possible with the Jul 16, 2021 · When your generator is overloaded, remove all the electronics connected to it then hit the circuit protector button after which you press the Overload Reset Button to correct its load. Difficulty in Startup. Jul 13, 2021 · New member here. Mission Statement: Supporting thoughtful exchange of knowledge, values and experience among RV enthusiasts. We have a 30amp trailer that is the Cherokee 264ck. With the connecting feature, this predator model is versatile and suitable for both light and mid-sized loads. Generac iQ3500 weighs 109 lbs and measures 23. Also, since it can work in parallel (but doesn't come with a parallel kit), its power can be doubled by connecting it to a second unit that works with it. Get our best deals and latest news delivered straight to you. engine # 580193-10/me11000532 15/410 please email any information Thank You Al Rich Jensen - 02/6/2023 at 10:04 pm As a whole, the Predator 3500 is certainly a worthy investment for anyone looking for power off the grid. Jul 25, 2019 · HF Predator 3500 Owners Please. Make absolutely sure that you don't have spark because 9/10 times it's a fuel issue. This gives it a running and starting wattage of 3500w and 4000w respectively against 3000w and 3500w for the predator 3500. Its controls and components have a 2-year operation guarantee. 7 inches, making it a bit more lightweight than Predator 3500 (110 lbs and 22. This makes it more easier to move around. Keep reading for more things that Mar 27, 2024 · The Predator 3500 Watt Super Quiet Inverter Generator is a fantastic choice for DIYers, contractors, campers, or anyone needing a reliable, portable power source. Ohio & Lady Lake Fl. Try to disconnect it and see if that solves the issue. Predator 3500 watt inverter generator issue I have a predator 3500 watt inverter and the overload light is flashing with nothing hooked up and I just put a new inverter in it comments sorted by Best Top New Controversial Q&A Add a Comment Don't bother installing the battery. One year old. When it is propane powered it will provide 3150w and 3600w. If the OVERLOAD light turns on and the Generator stops producing power, Predator 3500 Watt, 59137 - SUPER QUIET Inverter Today we will take in-depth the predator 3500 generator overload problem, predator 3500 generators no spark, predator 3500 generators leaking oil, and more. This Harbor Freight generator is called a very good workhorse for a mid-size unit. OFF RUN ART OIL OVERLOAD UT ARAL OUTLTS T AC 120V ET DC 12V ESCTTLE Only use OUTSIDE and far away from windows, doors, and vents. This is because the low- oil sensor is triggered therefore, it automatically disables the engine from turning on so that it can prevent further damage to the engine. 5 days later town gets hit by tornado and still no power. Wait for the engine to cool and remove the spark plug wire before performing any repairs. This generator also comes with a parallel kit that allows you to connect two units to double the power. Harbor Freight buys their top quality tools from the same factories that supply our competitors. Location: N. Some people have a different style of maintenance. It provides 2000 watts of starting Key Factors Concerning Predator 3500 Generator. to/39b02NcHere's a link to the NGK spark plug I installed on the 3500 watt generato Jul 28, 2023 · Based on the information provided, it is likely that the issue with the Predator 3500 Generator is related to either a bad spark plug, a fuel delivery issue, or a problem with the carburetor. Verdict. It has been fine until recently it has stopped producing power but it's running fine. com Quick Fact: Replacement parts for Predator 3500 like battery cover, fuel strainer and more are available for purchase at Harbor Freight Tools. 2. A faulty or dirty spark plug can hinder the ignition process, causing difficulty in startup. Apr 22, 2023 · The gasoline-powered 212 cc OHV 4-stroke engine is the heart of the Predator 3500. Next, check the air filter and clean or replace it if necessary. Note: Predator 3500 Watt, 59137 - SUPER QUIET Inverter Generator Manual 1 . predator 3500 overload problems. I have a 2500 watt predator generator that I purchased about six years ago. We have tested the load for the various equipment she uses and it doesn't approach the 3000W continuous load limit. I had to unplug the low oil sensor last year to get it to stay running. Sep 14, 2021 · Showing how to fix the generator overload #predator3500 #step by step Aug 5, 2020 · DIY EASY FIX FOR PREDATOR GENERATOR Download Predator 70143 PDF manual. If there is still no spark at this The predator 3500 also comes with four transportation wheels which lack in the Generac iQ3500. If the bulb is not tripping, this means that the GFCI receptacle is working well. In contrast, Predator 3500 features four built-in wheels, so it only comes down to a matter of preference to decide which May 3, 2022 · Replace the GFCI receptacle. com/ythiJustAnswer Customer: I have a predator 2000 generator . Environmental Protection Agency. The overload protection unit keeps the power supply regulated and clean regardless of the type of device you attach to the generator. Recently while camped in the desert at 7000' on a day with the outside temps running in the 90's,our gen went into overload mode and I am looking for reasons why. Now that’s cool. 6. With a 212 cc (6 hp) OHV 4-stroke engine, the Predator 3500 operates on gasoline, providing 120V, with a running wattage of 3,000W and a starting wattage of 3,500W. 4 hours. Running like a champ. If the OVERLOAD light turns on and the Generator stops producing power, it has been spark plug fouling and AC Overload Sep 30, 2023 · The Predator 3500 comes with a 90-day warranty. Let’s discuss some important factors to consider. If the OVERLOAD light turns on continuously and the Generator stops producing power, it has been overloaded. It delivers enough power for most tools, is surprisingly quiet, and the added safety features offer reassurance. Sep 16, 2017 · I thought the propose of eco mode, or in the case of the Predator ESC mode, was to lower fuel consumption by reducing rpms at lesser loads. If the color is blue you are fine. If you have similar needs, I wholeheartedly recommend it. The Void of Warranty Risk with Modification. Another potential cause could be insufficient fuel or a blockage in the fuel line. To learn more about the Predator generator, just continue to read our article. May 13, 2024 · This generator has an electronic overload protection feature. Jul 22, 2018 · Generator would not fire because of faulty low oil sensor . Apr 16, 2018 · My daughter has a mobile grooming trailer with a Predator 3500 Inverter generator from Harbor Freight. When you doubt your power, you give power to your doubt. Note: The OVERLOAD light may turn on for a few seconds as a large device starts up. The noise definitely ratchets up as you draw more power from the engine, but it tops out around 65 dB. This is a very respectable 750W average load for 11-hours. 5:1 Engine Type Horizontal Single Cylinder 4-stroke, OHV Cooling System Forced air cooled Fuel Type 87+ octane, stabilizer-treated unleaded gasoline Capacity 2. There are also safety breakers to come with the outlets, preventing you from unexpected injuries. Overload Light. For a generator capable of producing 3,000 watts of power for hours on end, the Predator 3500 is surprisingly quiet. That said, you only do this if your overload indicator light stays off. The low-oil sensor could be stuck. 6 gallon gas tank filled, the Predator 3500 can achieve an incredible 11-hours runtime at 25% load. The Champion 4000 produces more power than the Predator 3500. The total combined load through the outlet on the Generator must not exceed the running power of the unit. 6 gallons, while the Honda EU3000is has a fuel tank capacity of 3. 212cc air-cooled OHV gas engine, hassle free electric start for quick and easy starting. 2 hours. Aug 27, 2023 · Noise level. To prevent this from happening, make sure not to exceed the wattage capacity of your generator by using too many power-hungry appliances at once or Mar 24, 2022 · How to get full (maximum) power from a Harbor Freight Predator 3500 Inverter generator, for camping, job site work, or emergency home backup. This compact unit is comes with a bunch of great features and benefits all for an affordable price. It’s best to check if the breaker is damaged or working in prime condition. One of the most common issues that people report getting on the Predator 3500 generator is that it shuts down while they were using it. justanswer. Write the product’s serial number in the back of the manual (or month and year of purchase if product has no number). Pros and Cons of the Predator 3500 Pros. Features. This means that the Honda EU3000is can run for longer periods without needing a refill, making it a better option for those who need a generator for extended periods. If the generator has been overloaded for a while before you notice the issue, always use the Overload Reset Button before you use it again. 3 x 20 inches). 030. Feb 18, 2023 · Here are a few techniques and tricks you can use to fix an overloaded generator: First, check the oil level and add oil if needed. One of the most common symptoms of generator overload is that it will stop powering whatever it is currently running and go into an overload situation. 3. Page 2 For generator technical questions, please call 1-800-444-3353. Remove the Oil Drain Bolt, tilt the Generator slightly to facilitate drainage and wait for oil to drain completely. Now, when the generator is switched on, connect it to a load and see if the overload indicator still blinks. Aug 1, 2023 · Some reviewers call the Predator 3500 a very quiet device. 7 x 18 x 21. To remove it and check if it is dirty, clean it and check the spark if works place it back if not buy a new one. By; On 6th October 2022; with A faulty or dirty spark plug is another reason for surging in the Predator 3500 generator. Never May 18, 2024 · In this case, the predator 3500 comes with an electronic overload protection, which ensures your device is safe from damage each time. The 3500 can be taken anywhere with you, thanks to its weight of 99. Portable design and light enough to carry it easily; Creates less noise than a refrigerator; Can be parallel connected to another unit; Comes with an LCD screen to monitor output, overload, and oil. The champion has uses dual-fuel technology that allows it to maximize on clean energy. As for the Predator 3500, it provides you with low oil, overload, and light indicators. Reconnect electrical equipment if the overload warning light has gone out and the output light has come back on. Mar 30, 2023 · The Predator 3500 features overload protection and low oil shutdown like other models. It is useless. All the technical details about the new Harbor Freight Predator 9500 Generator you'd ever want to know, including outlet wiring, see the power waveform on an So I recently bought a 3500 from harbor freight and I’ve used it only about 12 hours and those hours I’ve just used it for my electric pressure washer and a water pump but today i fired it up and it was running a little until i just hear my pump go out and my pressure washer and see that it had an overload light on and i looked some things up and it said to check if the spark arrestor was Apr 26, 2020 · My daughter has a mobile grooming trailer with a Predator 3500 Inverter generator from Harbor Freight. When you start the machine, it should be in the closed position. Digital LCD screen with low oil, overload and output light indicators. It’s even fairly quiet in operation. The third bolt at the bottom of the air cleaner requires just a little bending of a bracket. If the button stays down, connect the generator to a small load directly. Nov 1, 2021 · Predator inverter generator power issues. 2 lbs. Step 4. If there is no reset button, turn off the system and wait a few Mar 17, 2019 · Propane Natural gas Conversion Kit for Generators on Amazon: https://amzn. Feb 4, 2023 · The Predator 3500 generator has a gas tank capacity of 4. Bypassed sensor to continue running. Oct 16, 2022 · Predator 3500 Fires then Dies-Not Oil Sensor. The 3500 electric start generator also has a manufacturer warranty for up to two years. In summary, the iQ3500 has better fuel efficiency and, by the same token, a longer runtime on average. This predator 3500 has an electric button for an easy and quick start. 6 gallons, and at 50% load can power appliances for up to 12. The iQ3500 and Predator 3500 have their own strong points. Everytime we run the ac even with nothing else on it continues to go into overload. The Running Period Per Fuel Tank. Oil, Ratio Rite, Checking Oil Level, Non-ethanol Fu . 6 Gallons Aug 2, 2021 · In contrast, the Predator 3500 comes with two years. After the 128 second test that the surge guard performs, it clicks/tries to send power through it into If you own a Predator 3500 generator, it is important to be aware of the potential for overload problems. This is a group for anyone who owns or is interested in the Harbor Freight Predator 8750 Inverter Generator. Additionally, the run time may also be further extended if you are to use Jul 13, 2023 · Disconnect the Ignition Module: Every ignition module has a ground wire attached to it. Generator Keeps Shutting Down. Yesterday I noticed the display was backlit after sitting for a couple weeks. This method also helps to refresh the resets’ number. Wondering if someone can lead me in the write direction. One common reason your Predator 2500 generator may struggle to start could be due to a problem with the spark plug. The Predator 2000-watt inverter generator is an excellent choice for low-power uses. The Predator 3500 generator is designed to be a fuel-efficient machine. After the connection is ready, wait for a minute to see if there is any tripping happening. If the overload warning light is still on, turn the generator off and take it to the repair shop. If that still doesn't work and you for sure don't have spark then its time to tear the engine apart and get to the coil on the flywheel. JustAnswer Customer: The overload light stays onPearl Wilson: Assi I bought a Predator 3500 watt inverter which recently won't deliver much power. I have a 3500 with 300 hours on it. This makes the generator an ideal choice for camping trips, emergency power, and other outdoor activities. This is normal for loads approaching the capacity of this Generator. You’ll love the generator’s fuel efficiency, translating to longer engine times per gasoline tank. A Predator generator won’t start due to a dirty carburetor, plugged fuel filter, plugged fuel tank vent, bad spark plug, plugged air filter, wrong choke setting, low engine oil, or old fuel. This can be quite annoying to deal with but you should note that several things can cause this issue on your device. Recheck for Spark: With the ground wire disconnected, pull the engine over once again. Is this the quietest generator? Harbor Freight 3500 PREDATOR generator honest review. If you have 2 A/c units, shut one off at the breaker. 1. To make sure the battery was not drained I attempted to start it. A Predator generator starts then dies due to an empty fuel tank, plugged fuel filter, dirty carburetor, clogged fuel line, bad gas cap, dirty spark plug, faulty ignition coil, low engine oil level, or old gas. In this video I show how I fixed the common surging problem with the Predator 3500 Generator from Harbor Freight. 3 x H20 in), provides an esthetical advantage over any ordinary, open frame product. The only weak spot is that oil drain at the bottom of the housing. Setting up a new Predator 3500 Inverter Generator. Fuel Efficiency. Follow the safety precautions found in the Dec 10, 2023 · Even if the engine continues to run. 3 x 20 inches this generator is still capable of being brought on the road and tucked away safely without taking up too much room. My daughter has a mobile grooming trailer with a Predator 3500 Inverter generator from Harbor Freight. It's a quarter sized, tight fitting rubber stopper. Aug 16, 2023 · Typically this will involve pressing and holding the machine’s reset button for more than one second. However, restarting the generator using the power switch also does the trick, but not always. And so, they may want to convert it into a propane runnable option. Predator 3500 The predator 3500 Inverter generator won’t start if there is low oil levels in the crankcase. That said, the Predator 3500 has a fuel tank capacity of 6. The generator’s enclosure helps reduce noise and makes the generator ultra-quiet. Download Predator 59186 PDF manual. However, you should also ensure that the generator is on a flat surface when you are Apr 14, 2024 · Anyway, it took an hour of removing panels and a leaf blower to remove to remove it all. Then restart the generator. Replacing any malfunctioning components should fix the issue and allow the generator to start and run properly. Jun 17, 2022 · How to restart Champion 2800 Watt Inverter Generator when overloaded. Disconnect it from the ignition coil kill wire and see if the engine still shuts down. We bought the predator 3500 inverter. For spark, replace the stock plug with an NGK BP6 or similar. Why my Predator 3500 inverter Generator is Overheating: Overheating in another Predator 3500 generator’s problem which I faced a few times. We cut out the middleman and pass the savings to you! good morning I have a Predator 3500 inverter i need valve train parts , retainers springs, and valves. Jun 24, 2020 · So You can go with a true 2200 peak and a soft start kit added to the A/C or you can get a beefy 3500 like Airstream likes. Predator 3500 vs Generac 3500 – A Comparison Overview Predator 3500 – Overview. However, if you do not get a spark, then there is a problem with the engine coil. Before resetting it, press the overload reset button once to reset the settings. We would definitely recommend this to anyone looking for a versatile, compact inverter generator for Jan 30, 2021 · The Predator 3500’s characteristic encased inverter generator design (L22. The Predator 3500 produces 3500 watts surge power and 3000 watts continuous power. Any input as to why it may keep going into overload. Alas, I can only run either one for 5-10 minutes before the generator goes into overload condition OVERLOAD OUTPUT A RLLEL OUTS T A C 120VET DC 12V ESC THRO TTLE RUN ART L O RLOAD OUTPUT RALLEL OUTLE TS SE C S DC 12V ESC THRO TTLE NEVER use inside a home or garage, EVEN IF doors and windows are open. After that, there are still certain cases where the overload light on inverter generators stays on. Jan 29, 2021 · From https://www. Shut the inverter off and reduce the appliance load. Turn the inverter back on and if the overload message is still there, use the reset button. Flood the day after and was able to power pumps to remove water. Overloading can cause serious damage to the engine and even lead to complete breakdown. Any tips would be predator@harborfreight. If you have ever heard of the predator 3500 Generator and thought of purchasing it, take a deeper look at its advantages and disadvantages, and then decide. ITEM 61169 For engine technical questions, please call 1-800-520-0882. This video is not for mechanics (WILL)!!!! Jul 13, 2020 · Originally Posted by Btscdavis. Look for a bad starter solenoid, weak battery, or bad ignition switch on Predator generators with an electric start. I also had to use a fine pick to remove a few pieces of insulation from inside the alternator. Predator 2000 Watt Super Quiet Inverter Generator. Tilt the Generator and replace the Drain Plug, then set the Generator back down on a level surface. For warranty information, refer to the last pages of this manual. The only wire that should remain connected to the module is the spark plug lead. 11 hour run-time at 25% capacity. I purchase a Wen GN400i 3500/4000w inverter generator hoping to be able to run at least one of the AC units. I do an in-depth review on the Harbor Freight Predator Generator 3500 i Power & Run Time. She has a problem with the overload protection activating when the load is only about 60% of the rated load. The generator is sealed up pretty good. May 27, 2022 · Pushing this button in will help to reset the breaker. My Predator 3500 just quit running. Apart from the features mentioned above, the Fortunately there are ways to fix an inverter overload, and you can try these solutions first before calling for customer support. It provides the information you want Mar 25, 2024 · With the 2. S. CarBOn Oct 19, 2021 · Predator 3500 Generator Problems Troubleshooting. I am also a cut dry person in a low budget land so I went with Harborfreight predator 3500. In addition, the device is parallel capable ( parallel kit not included) and thus, can be linked to a similar or compatible unit for added power. At 25% load, the generator can run for an estimated 16. com Owner’s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. This inverter generator has a noise rating of 56 dBA, which is quieter than Mission Statement: Supporting thoughtful exchange of knowledge, values and experience among RV enthusiasts. yc av vy mv yy bn js po fb fw